OHAUS Electronic Balance, PX84 AM OHAUS Electronic Balance, PX84/E AM OHAUS Electronic Balance, PX124 AM OHAUS Electronic Balance, PX124/E AM OHAUS Electronic Balance PX224 AM OHAUS Electronic Balance, PX224/E AM

SKU: VOHS-30429837 VOHS-30429845 VOHS-30429838 VOHS-30429846 VOHS-30430053 VOHS-30429847

Availability: In Stock In Stock In Stock In Stock In Stock In Stock

Regular price $2,130.00 $1,810.50
Warranty, Shipping and Return Info

Warranty

  • All products are shippined directly from the Manufacturer come with a one (1) year warranty, except when specified in the description

Shipping Informtaion

  • This product ships directly from the Manufacturer
  • Product usually ships within two business days
  • Expedited and international shipping not available at this time
  • For any additional information or special order requests please contact customer service here

Returns Information

  • AmScope offers a 30 day return policy from the purchase date of your oder. If the item does not meet your needs or satisfaction, please contct us within 30 days for an RMA (Return of Merchandise Authorization) number. Returns must be new, unused and repackaged in the original shipping materials in order to receive a full refund
  • Customer is responsible for the cost of shipping for returned products
  • Returns may be subject to a 20% restocking fee. Please ask us about this when you call to arrange your return
Model*
Capacity*
Readability*

The Higher the Magnification - The More Detail You'll See

Magnification 40x
Magnification 1000x
Magnification 2500x

Magnification is the ability of your microscope to make small objects seem larger. As the magnification increases the area being viewed will be decrease is size but the detail of the area being viewed will improve.

Amscope microscopes come with multiple magnifications to aid you in finding the proper magnification for viewing each specimen.

Camera Connection Types

When comparing 2.0 and 3.0 there are few major differences. First the transfer rates. USB 2.0 offers transfer rates of 480 Mbps and USB 3.0 offers transfer rates of 4.8 Gbps - that's 10 times faster.

Camera Resolution

The most important factor in ensuring successful microscopic imaging is choosing the appropriate optics and camera for your application that gives you more data and higher image quality. When selecting a microscope camera, it is best to base your decision on the most important requirements for your microscopic observation.

* Required Fields

Key Features

    • The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point.
    • Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use.
    • PX features a second line display for additional information/guidance, & USB/RS232 connectivity for easy communication. Draftshield models feature a static removal (ESR) bar for convenient grounding.
    • The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point.
    • Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use.
    • PX features a second line display for additional information/guidance, & USB/RS232 connectivity for easy communication. Draftshield models feature a static removal (ESR) bar for convenient grounding.
    • The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point.
    • Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use.
    • PX features a second line display for additional information/guidance, & USB/RS232 connectivity for easy communication. Draftshield models feature a static removal (ESR) bar for convenient grounding.
    • The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point.
    • Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use.
    • PX features a second line display for additional information/guidance, & USB/RS232 connectivity for easy communication. Draftshield models feature a static removal (ESR) bar for convenient grounding.
    • The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point.
    • Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use.
    • PX features a second line display for additional information/guidance, & USB/RS232 connectivity for easy communication. Draftshield models feature a static removal (ESR) bar for convenient grounding.
    • The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point.
    • Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use.
    • PX features a second line display for additional information/guidance, & USB/RS232 connectivity for easy communication. Draftshield models feature a static removal (ESR) bar for convenient grounding.
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 82 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration InCal™ - Semi Automatic
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 82 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration Not Applicable
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 120 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration InCal™ - Semi Automatic
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 120 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration Not Applicable
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 220 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration InCal™ - Semi Automatic
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 220 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration Not Applicable
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 82 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration InCal™ - Semi Automatic
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 82 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration Not Applicable
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 120 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration InCal™ - Semi Automatic
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 120 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration Not Applicable
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 220 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration InCal™ - Semi Automatic
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)
OVERVIEW
The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications
Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination
Display
Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)
Operation
AC adapter (included)
Communication
RS232 and USB device (included); GLP/GMP data output with real-time clock
Construction
Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover
Design Features
User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, userselectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages
SPECIFICATIONS
Maximum Capacity 220 g
Readability 0.0001 g
Pan Size 90 mm
Internal Calibration Not Applicable
Draftshield Included
Auxiliary Display Model Available as an Accessory
Battery Life Not Applicable
Communication RS232;  USB
Dimensions 309 mm x 321 mm x 209 mm (HxLxW)
Display 2-Line LCD with Backlight
In-use cover Included
Legal for Trade No
Linearity ± 0.0002 g
Minimum Weight (USP, 0.1%, typical) 200 mg
Net Weight 10 lb (4.5 kg)
Pan Construction Stainless Steel
Power AC Adapter (Included)
Repeatability (typical) 0.0001 g
Stabilization Time 3 s
Tare Range To capacity by subtraction
Units of Measurement Carat;  Custom;  Grain;  Gram;  Hong Kong Tael;  Kilogram;  Mesghal;  Milligram;  Momme;  Newton;  Ounce;  Ounce Troy;  Pennyweight;  Pound;  Singapore Tael;  Taiwan Tael;  Tical;  Tola
Working Environment 50°F – 86°F, 80%RH, non-condensing;  operability guaranteed between 41°F and 104°F (10°C – 30°C, 80%RH, non-condensing;  operability guaranteed between 5°C and 40°C)

People Also Viewed