AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen and 1.2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen and 2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen and 3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen and 6.3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen and 12MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-400X Magnification with 30W Halogen and 20MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen and 1.2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen and 2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen and 3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen and 6.3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen and 12MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-600X Magnification with 30W Halogen and 20MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen and 1.2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen and 2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen and 3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen and 6.3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen and 12MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-800X Magnification with 30W Halogen and 20MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen and 1.2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen and 2MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen and 3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen and 6.3MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen and 12MP USB 3.0 C-mount Camera AmScope IN300 Series Inverted Phase-Contrast Biological EPI-Fluorescent Trinocular Compound Microscope 40X-1000X Magnification with 30W Halogen and 20MP USB 3.0 C-mount Camera
Key Features
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 1.2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 1.2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 1.2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 1.2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
Applications | Clinic, Laboratory, Veterinary |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Operating System | Software |
---|---|
Windows | v.10.11.2024 |
MAC | AmScopeAmLite_20240408.dmg |
SDK | TPG SDK (Optional) v.03.11.2024 |
Linux | AmScopeAmLite_x64_x84_20231115.tar |
AmScope products are warranted against manufacturer’s defects in material and workmanship from the original date of purchase, for the following years:
• Five Year Warranty for Microscopes: All our microscopes come with a five (5) year factory warranty against manufacturing defects, covering labor and parts.
• Ten Year Warranty for Euromex Microscopes: All our Euromex microscopes come with a ten (10) year factory warranty against manufacturing defects, covering labor and parts.
• One Year Warranty for Telescopes: All our telescopes come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Accessories: All our microscope accessories (USB cameras, illuminators, illumination, dust covers, and etc.) come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Items labeled as “Product Ships From Manufacturer”: All products that are shipped directly from the manufacturer come with a one (1) year warranty, except when specified in the description.
Warranty does not apply for consumable accessories and parts such as bulbs, batteries, fuses, cords, optical components or any add-on accessories such as mechanical specimen holders that are not built into the microscope stage as an integral part of the original manufacture, etc. Warranty does not cover microscopes, lenses cameras or other accessories that have become inoperable due to dirt or damage due to misuse or lack of maintenance.
Note: Buyers are responsible for return shipping and handling cost for warranty services. Our warranty covers parts and labor only.
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 1.2MP USB3.0 camera. With extraordinary sensitivity and high framerates, the MU123-FL provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 1.2MP back-illuminated CMOS sensor with an incredible 2040mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/3" |
Active Pixels | 1.2M (1280 x 960) |
Pixel Size | 3.75µm x 3.75µm |
Active Sensor Area | 4.80mm x 3.60mm |
Shutter | electronic rolling shutter |
Sensitivity | 2040mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 60fps @ 1280x960 120fps @ 640x480 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included for use with 23mm-30.5mm ports to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|