AmScope T800 High-performance Multi-band LED-Fluorescence Trinocular Compound Microscope
Key Features
- 3-band LED-excited fluorescence with multi-filter turret
- A robust, high-performance microscope with a wide range of contrast-enhancing methods available
- Infinity-corrected, plan, semi-apochromatic optics with edge-to-edge sharpness
- Koehler illumination with multi-NA swing-condenser for high and low magnification
Overview
The T800-FLLED upright fluorescence microscope uses a cutting-edge 3-LED illuminator for variable-band excitation. Oufitted with the widely-used green (G1), blue (B1), and ultraviolet (UV2) excitation-bands, it can be used for a wide variety of common labeling or autofluorescence. Unlike single-LED fluorescence illuminators, the three LEDs are cycled using a multi-filter turret, eliminating the need to exchange light-sources. Each LED provides a precise excitation-source to eliminate non-relevant light, as well as providing maximum intensity at the targeted wavelength. Another major benefit of LED illumination is the elimination of long warm-up times and other care required by fluorescent light-sources such as mercury-vapor.
The infinity-corrected optical system includes plan-fluor objectives, which provide edge-to-edge sharpness with higher resolution, improved color-correction, and improved short and long wavelength transmission. The reversed quintuple-nosepiece is equipped with 4X, 10X, 20X, 40X, and 100X plan semi-apochromatic lenses. The 10X plan, high-eyepoint eyepieces provide a compounded magnification range of 40X to 1000X. The Koehler illumination-system is designed for precision, with a variable-NA swing-condenser allowing the use of high and low magnifications with full, even coverage. The robust frame offers excellent stability and ergonomics, with coaxial coarse and fine focusing, as well as coaxial stage-translation knobs providing fluid control.
Fluorescence
Filters | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||
LED Excitation | ||||||||||||||||||||||||||||
|
Specifications
Optical System | Infinity-corrected |
Head | Trinocular, 30 ° incline, 360 ° rotatable |
Interpupillary Adjustment | Compensation-free gemel, 48-75mm |
Eyepieces | Plan 10X, high-eyepoint, FN 22mm, 30mm mount |
Photo-port | 1X focus-adjustable C-mount |
Nosepiece | Quintuple reversed |
Objective Lenses | 4X, 10X, 20X, 40X (spring), 100X (spring, oil) |
Focusing System | Coaxial coarse and fine focus, upper limit-stop, tension-control |
Focus Travel | 30mm, 0.002mm fine-adjustment |
Stage | Double-layer mechanical 185mm x 165mm |
X-Y Translation Range | 80mm x 55mm |
Sub-stage Condenser-holder | Rack-and-pinion, centerable |
Condenser | Achromatic swing condenser, NA1.2/0.22 |
Transmitted Illumination | 3W LED, 6V2A, continous adjustment |
Fluorescence Excitation Illumination | 3 x 3W LED: UV2(385nm), B1(470nm), G1(560nm) |
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | Plan Fluor | 0.13 | 15.13mm | 0.17mm |
10X | Plan Fluor | 0.30 | 8.53mm | 0.17mm |
20X | Plan Fluor | 0.50 | 2.33mm | 0.17mm |
40X | Plan Fluor | 0.75 | 0.55mm | 0.17mm |
100X | Plan Fluor | 1.28 | 0.21mm | 0.17mm |
Components
Objectives |
|
||||||||
Eyepieces |
|
||||||||
Condensers |
|
||||||||
Heads |
|
||||||||
Photo-ports (Trinocular Heads Only) |
|
||||||||
|
camera compatibility | None |
compatibility | None |
illumination style | Incident & Transmitted |
magnification type | Multi-Power |
Manufacturer | AmScope |
microscope application | Clinic, Laboratory, Teaching/Training |
microscope category | Compound |
microscope condenser design | Kohler |
microscope condenser optics | Other |
microscope condenser type | Brightfield, Kohler |
microscope eyepiece power | 10X |
microscope eyepiece size | 30mm |
microscope field view | Extreme Widefield |
microscope head style | Trinocular |
microscope light power | 3W |
microscope light shape | Built-in |
microscope light type | LED |
microscope objective power | 4X, 10X, 20X, 40X, 50X, 100X |
microscope objective size | 20mm |
microscope optics | Infinity, Plan |
microscope specialty | EPI-Fluorescence |
microscope stage | Two-layer Mechanical Stage |
optics | Infinity, Plan |
product condition | NEW |
prop 65 |
AmScope products are warranted against manufacturer’s defects in material and workmanship from the original date of purchase, for the following years:
• Five Year Warranty for Microscopes: All our microscopes come with a five (5) year factory warranty against manufacturing defects, covering labor and parts.
• Ten Year Warranty for Euromex Microscopes: All our Euromex microscopes come with a ten (10) year factory warranty against manufacturing defects, covering labor and parts.
• One Year Warranty for Telescopes: All our telescopes come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Accessories: All our microscope accessories (USB cameras, illuminators, illumination, dust covers, and etc.) come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Items labeled as “Product Ships From Manufacturer”: All products that are shipped directly from the manufacturer come with a one (1) year warranty, except when specified in the description.
Warranty does not apply for consumable accessories and parts such as bulbs, batteries, fuses, cords, optical components or any add-on accessories such as mechanical specimen holders that are not built into the microscope stage as an integral part of the original manufacture, etc. Warranty does not cover microscopes, lenses cameras or other accessories that have become inoperable due to dirt or damage due to misuse or lack of maintenance.
Note: Buyers are responsible for return shipping and handling cost for warranty services. Our warranty covers parts and labor only.
Overview
The T800-FLLED upright fluorescence microscope uses a cutting-edge 3-LED illuminator for variable-band excitation. Oufitted with the widely-used green (G1), blue (B1), and ultraviolet (UV2) excitation-bands, it can be used for a wide variety of common labeling or autofluorescence. Unlike single-LED fluorescence illuminators, the three LEDs are cycled using a multi-filter turret, eliminating the need to exchange light-sources. Each LED provides a precise excitation-source to eliminate non-relevant light, as well as providing maximum intensity at the targeted wavelength. Another major benefit of LED illumination is the elimination of long warm-up times and other care required by fluorescent light-sources such as mercury-vapor.
The infinity-corrected optical system includes plan-fluor objectives, which provide edge-to-edge sharpness with higher resolution, improved color-correction, and improved short and long wavelength transmission. The reversed quintuple-nosepiece is equipped with 4X, 10X, 20X, 40X, and 100X plan semi-apochromatic lenses. The 10X plan, high-eyepoint eyepieces provide a compounded magnification range of 40X to 1000X. The Koehler illumination-system is designed for precision, with a variable-NA swing-condenser allowing the use of high and low magnifications with full, even coverage. The robust frame offers excellent stability and ergonomics, with coaxial coarse and fine focusing, as well as coaxial stage-translation knobs providing fluid control.
Fluorescence
Filters | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||
LED Excitation | ||||||||||||||||||||||||||||
|
Specifications
Optical System | Infinity-corrected |
Head | Trinocular, 30 ° incline, 360 ° rotatable |
Interpupillary Adjustment | Compensation-free gemel, 48-75mm |
Eyepieces | Plan 10X, high-eyepoint, FN 22mm, 30mm mount |
Photo-port | 1X focus-adjustable C-mount |
Nosepiece | Quintuple reversed |
Objective Lenses | 4X, 10X, 20X, 40X (spring), 100X (spring, oil) |
Focusing System | Coaxial coarse and fine focus, upper limit-stop, tension-control |
Focus Travel | 30mm, 0.002mm fine-adjustment |
Stage | Double-layer mechanical 185mm x 165mm |
X-Y Translation Range | 80mm x 55mm |
Sub-stage Condenser-holder | Rack-and-pinion, centerable |
Condenser | Achromatic swing condenser, NA1.2/0.22 |
Transmitted Illumination | 3W LED, 6V2A, continous adjustment |
Fluorescence Excitation Illumination | 3 x 3W LED: UV2(385nm), B1(470nm), G1(560nm) |
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | Plan Fluor | 0.13 | 15.13mm | 0.17mm |
10X | Plan Fluor | 0.30 | 8.53mm | 0.17mm |
20X | Plan Fluor | 0.50 | 2.33mm | 0.17mm |
40X | Plan Fluor | 0.75 | 0.55mm | 0.17mm |
100X | Plan Fluor | 1.28 | 0.21mm | 0.17mm |
Components
Objectives |
|
||||||||
Eyepieces |
|
||||||||
Condensers |
|
||||||||
Heads |
|
||||||||
Photo-ports (Trinocular Heads Only) |
|
||||||||
|