AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-400X Magnification with 1.5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-400X Magnification with 2.3MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-400X Magnification with 3.1MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-400X Magnification with 3.1MP Monochrome Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-400X Magnification with 5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-400X Magnification with 9MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-600X Magnification with 1.5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-600X Magnification with 2.3MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-600X Magnification with 3.1MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-600X Magnification with 3.1MP Monochrome Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-600X Magnification with 5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-600X Magnification with 9MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-800X Magnification with 1.5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-800X Magnification with 2.3MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-800X Magnification with 3.1MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-800X Magnification with 3.1MP Monochrome Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-800X Magnification with 5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-800X Magnification with 9MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-1000X Magnification with 1.5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-1000X Magnification with 2.3MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-1000X Magnification with 3.1MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-1000X Magnification with 3.1MP Monochrome Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-1000X Magnification with 5MP Color Global Shutter Camera AmScope IN300 Series Inverted Epi-fluorescence Trinocular Compound Microscope 40X-1000X Magnification with 9MP Color Global Shutter Camera
Key Features
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes an ultra-sensitive 1.5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 2.3MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive monochrome 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 400X magnification range using a quadruple lens turret for four unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 9MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes an ultra-sensitive 1.5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 2.3MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive monochrome 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 600X expanded magnification range using a quadruple lens turret and additional 15X eyepieces for eight unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 9MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes an ultra-sensitive 1.5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 2.3MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive monochrome 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 800X expanded magnification range using a quadruple lens turret and additional 20X eyepieces for six unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 9MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes an ultra-sensitive 1.5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 2.3MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive monochrome 3.1MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 5MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
- 40X to 1000X expanded magnification range using a quadruple lens turret and additional 25X eyepieces for seven unique settings.
- An inverted epi-fluorescence microscope with blue and green excitation blocks and a high-power HBO arc-lamp for broad-spectrum coverage.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X and 20X objective lenses are included for phase-contrast applications.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Includes a highly-sensitive 9MP USB 3.0 camera with global-shutter technology and specialized microscopy software for PC, Mac, and Linux
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 0.4MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 0.4M (720 x 540) |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mercury HBO Excitation | ||||||||||||
| ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 1.5MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
| ||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity | ||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 1.5M |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
- One microscope body
- Four objectives lenses: 4X, 10X(Ph), 20X(Ph) and 40X
- One pair 10X eyepieces
- One pair 15X eyepieces
- One phase-contrast annulus board
- One top-mount illuminator
- One rear-mount fluorescence illuminator
- One power supply for fluorescence illuminator
- One UV blocking shield
- One 30W halogen bulb
- One 100W mercury bulb
- One dust cover
- Color filters
- Two power cords
- One C-mount USB camera
- One 0.37X reduction lens
- Two sizing adapters
- One USB 3.0 Type B to USB 3.0 type A cable
- One software CD
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mercury HBO Excitation | ||||||||||||
| ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 0.4MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
| ||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity | ||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 1.5M |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
- One microscope body
- Four objectives lenses: 4X, 10X(Ph), 20X(Ph) and 40X
- One pair 10X eyepieces
- One pair 20X eyepieces
- One phase-contrast annulus board
- One top-mount illuminator
- One rear-mount fluorescence illuminator
- One power supply for fluorescence illuminator
- One UV blocking shield
- One 30W halogen bulb
- One 100W mercury bulb
- One dust cover
- Color filters
- Two power cords
- One C-mount USB camera
- One 0.37X reduction lens
- Two sizing adapters
- One USB 3.0 Type B to USB 3.0 type A cable
- One software CD
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mercury HBO Excitation | ||||||||||||
| ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 0.4MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
| ||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity | ||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 1.5M |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
- One microscope body
- Four objectives lenses: 4X, 10X(Ph), 20X(Ph) and 40X
- One pair 10X eyepieces
- One pair 25X eyepieces
- One phase-contrast annulus board
- One top-mount illuminator
- One rear-mount fluorescence illuminator
- One power supply for fluorescence illuminator
- One UV blocking shield
- One 30W halogen bulb
- One 100W mercury bulb
- One dust cover
- Color filters
- Two power cords
- One C-mount USB camera
- One 0.37X reduction lens
- Two sizing adapters
- One USB 3.0 Type B to USB 3.0 type A cable
- One software CD
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-400X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-600X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-800X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Applications | Clinic, Laboratory, Veterinary |
Camera Compatibility | PC & Mac |
Camera Sensor Type | CMOS |
Camera Type | USB 3.0 GS |
Categories | Microscopes, Compound Microscopes, Special Microscopes, Special Microscopes/Phase Contrast, Special Microscopes/EPI-Fluorescence, Special Microscopes/Inverted, Applications/Chemistry Microscopes, Applications/Medical & Microbiology Microscopes, Applications/Botany Microscopes/Phytopathology, Applications/Chemistry Microscopes/Biochemistry Microscopes, Applications/Chemistry Microscopes/Biotechnology Microscopes, Applications/Chemistry Microscopes/Pharmaceutics Microscopes, Applications/Medical & Microbiology Microscopes/Bacteriology, Applications/Medical & Microbiology Microscopes/Biochemistry, Applications/Medical & Microbiology Microscopes/Cell Culture, Applications/Medical & Microbiology Microscopes/Cytology, Applications/Medical & Microbiology Microscopes/Gout & Rheumatology, Applications/Medical & Microbiology Microscopes/Fluorescence, Applications/Medical & Microbiology Microscopes/Neuropathology, Applications/Medical & Microbiology Microscopes/Oncology, Applications/Medical & Microbiology Microscopes/Pathology, Applications/Medical & Microbiology Microscopes/Virology, Compound Microscopes/Brightfield, Student Microscopes/Graduate Student & Research Microscopes, Compound Microscopes/Phase Contrast, Compound Microscopes/EPI-Fluorescence, Compound Microscopes/Inverted |
Condenser Type | Brightfield, Phase Contrast |
Education Level | College, Teaching/Training |
Eyepiece Mounting Size | 30mm |
Field of View Class | Extreme Widefield |
Head Style | Trinocular |
Illumination Bulb Count | 2 |
Illumination Power | 30W, 100W |
Illumination Style | Incident & Transmitted |
Illumination Type | Halogen, Fluorescent |
Iris | With Iris |
Magnification | 40X-1000X |
Magnification Type | Multi-Power |
Objective Lens Power | 4X, 10X, 20X, 40X |
Objective Mounting Size | 20mm |
Optics | Plan, Infinity |
Power Compatibility | 110V |
product condition | NEW |
Product Type Category | Compound |
Operating System | Software |
---|---|
Windows | v.10.11.2024 |
MAC | AmScopeAmLite_20240408.dmg |
SDK | TPG SDK (Optional) v.03.11.2024 |
Linux | AmScopeAmLite_x64_x84_20231115.tar |
AmScope products are warranted against manufacturer’s defects in material and workmanship from the original date of purchase, for the following years:
• Five Year Warranty for Microscopes: All our microscopes come with a five (5) year factory warranty against manufacturing defects, covering labor and parts.
• Ten Year Warranty for Euromex Microscopes: All our Euromex microscopes come with a ten (10) year factory warranty against manufacturing defects, covering labor and parts.
• One Year Warranty for Telescopes: All our telescopes come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Accessories: All our microscope accessories (USB cameras, illuminators, illumination, dust covers, and etc.) come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Items labeled as “Product Ships From Manufacturer”: All products that are shipped directly from the manufacturer come with a one (1) year warranty, except when specified in the description.
Warranty does not apply for consumable accessories and parts such as bulbs, batteries, fuses, cords, optical components or any add-on accessories such as mechanical specimen holders that are not built into the microscope stage as an integral part of the original manufacture, etc. Warranty does not cover microscopes, lenses cameras or other accessories that have become inoperable due to dirt or damage due to misuse or lack of maintenance.
Note: Buyers are responsible for return shipping and handling cost for warranty services. Our warranty covers parts and labor only.
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 0.4MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 0.4M (720 x 540) |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mercury HBO Excitation | ||||||||||||
| ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 1.5MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
| ||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity | ||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 1.5M |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
- One microscope body
- Four objectives lenses: 4X, 10X(Ph), 20X(Ph) and 40X
- One pair 10X eyepieces
- One pair 15X eyepieces
- One phase-contrast annulus board
- One top-mount illuminator
- One rear-mount fluorescence illuminator
- One power supply for fluorescence illuminator
- One UV blocking shield
- One 30W halogen bulb
- One 100W mercury bulb
- One dust cover
- Color filters
- Two power cords
- One C-mount USB camera
- One 0.37X reduction lens
- Two sizing adapters
- One USB 3.0 Type B to USB 3.0 type A cable
- One software CD
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 15X eyepieces expand the maximum magnification to 600X with 8 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 15X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mercury HBO Excitation | ||||||||||||
| ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 0.4MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
| ||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity | ||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 1.5M |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
- One microscope body
- Four objectives lenses: 4X, 10X(Ph), 20X(Ph) and 40X
- One pair 10X eyepieces
- One pair 20X eyepieces
- One phase-contrast annulus board
- One top-mount illuminator
- One rear-mount fluorescence illuminator
- One power supply for fluorescence illuminator
- One UV blocking shield
- One 30W halogen bulb
- One 100W mercury bulb
- One dust cover
- Color filters
- Two power cords
- One C-mount USB camera
- One 0.37X reduction lens
- Two sizing adapters
- One USB 3.0 Type B to USB 3.0 type A cable
- One software CD
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 20X eyepieces expand the maximum magnification to 800X with 6 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 20X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mercury HBO Excitation | ||||||||||||
| ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 0.4MP monochrome camera is the most sensitive camera we carry, with extremely fast maximum framerates. It uses a cutting-edge Sony global-shutter sensor which is designed to excel in low-light, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
| ||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity | ||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/3" |
Active Pixels | 1.5M |
Pixel Size | 6.9µm x 6.9µm |
Active Sensor Area | 4.97mm x 3.73mm |
Shutter | global shutter |
Sensitivity | 7469mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 520fps @ 720x540* *Maximum framerate is for preview only. Recorded framerate will depend on computer hardware, including CPU, GPU, and hard drive. Software codecs may limit recorded framerate depending on compression. |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
- One microscope body
- Four objectives lenses: 4X, 10X(Ph), 20X(Ph) and 40X
- One pair 10X eyepieces
- One pair 25X eyepieces
- One phase-contrast annulus board
- One top-mount illuminator
- One rear-mount fluorescence illuminator
- One power supply for fluorescence illuminator
- One UV blocking shield
- One 30W halogen bulb
- One 100W mercury bulb
- One dust cover
- Color filters
- Two power cords
- One C-mount USB camera
- One 0.37X reduction lens
- Two sizing adapters
- One USB 3.0 Type B to USB 3.0 type A cable
- One software CD
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 2.3MP digital camera uses a cutting-edge global-shutter CMOS sensor which provides better motion-rendering, eliminating rolling-shutter artifacts. The new design based partly on CCD architecture provides extremely-high sensitivity, ideal for fluorescence microscopy and other low-light applications. In brightfield applications, the camera can record up to 30fps. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.2" |
Active Pixels | 2.3M (1920 x 1200) |
Pixel Size | 5.86µm x 5.86µm |
Active Sensor Area | 11.25mm x 7.03mm |
Shutter | global shutter |
Sensitivity | 1016mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30fps @ 1920x1200 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.37X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The ultra-sensitive 3.1MP camera uses a cutting-edge monochrome Sony global-shutter sensor. The monochrome sensor is more efficient due to the lack of a color-filter array, maximizing the amount of light absorbed. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (monochrome) |
Sensor Optical Format | 1/1.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 7.07mm x 5.3mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 53fps @ 2048x1536 85fps @ 1024x768 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 5MP camera uses a cutting-edge Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 2/3" |
Active Pixels | 5M (2448 x 2048) |
Pixel Size | 3.45µm x 3.5µm |
Active Sensor Area | 8.45mm x 7.07mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 35fps @ 2448x2048 88fps @ 1224x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN300T-FL is an inverted fluorescence microscope built for professional laboratories and universities focused on live-cell studies and a range of genetic research. It provides all of the necessary features for fluorescence, brightfield, and phase-contrast microscopy in an intuitive and economical design. Plan-fluor lenses provide a higher level of optical corrections and resolution for improved clarity.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the right ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. The 23mm photo port is height-adjustable to match focus with the eyepieces.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quadruple objective turret provides instant access to 4 magnification levels. This allows you to efficiently move through magnifications from 40X to 400X. Additional 25X eyepieces expand the maximum magnification to 1000X with 7 unique levels. These high-quality lenses are semi-apochromatically corrected for superior optical corrections and transmittance, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement.
Transmitted Illumination
The transmitted illumination system uses a fixed-height, 30W incandescent light-source with integrated condenser, and slots for filters and a phase-annulus board. The annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Phase Contrast
The 10X and 20X objective lenses are equipped with phase rings for phase-contrast observation. By sliding the provided phase-annulus board into the overhead lamp, the transmitted lighting is quickly changed to work with the objective lenses to enhance contrast in hard-to-see samples such as live cells which cannot be stained. By manipulating variances in phase caused by changing refractive indices, once imperceptible details can present as transitions from dark to light.
Epi-fluorescence Illumination
For fluorescence applications, a 100W mercury-vapor arc lamp provides a powerful, broad-spectrum light-source for excitation. The included blue and green excitation filter blocks cover a large range of popular fluorophores. Optional ultraviolet and violet excitation filters are also available.
Fluorescence
Filters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
Mercury HBO Excitation | ||||||||||||
Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.
|
Digital Imaging
The highly-sensitive 9MP camera uses a cutting-edge 1"-format Sony global-shutter sensor. The camera is designed to excel in low-light with high maximum framerates, and eliminates rolling-shutter distortion. The camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features and specialized tools for fluorescence color-mapping. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
Specifications
Optical System | Infinity-corrected | ||||
Head | Trinocular, 45° incline | ||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-75mm | ||||
Ocular Diameter | 30mm | ||||
Ocular Diopters | right ocular | ||||
Eyepieces | 10X, 25X | ||||
Photo-port | height-adjustable 23mm tube | ||||
Objective Lenses | Infinity-corrected | ||||
Objective Turret | Quadruple | ||||
Focusing System |
|
||||
Stage | fixed-height, mechanical X-Y translation | ||||
Stage Dimensions | 172mm x 242mm | ||||
Stage X-Y Travel Range | 75mm x 40mm | ||||
Specimen Holders | Terasaki plate, Petri dish | ||||
Episcopic Illumination (Fluorescence) | 100W mercury HBO arc-lamp, centerable | ||||
Transmitted Illumination | 12V 30W halogen variable intensity |
||||
Condenser | NA 0.3, iris diaphragm, filter slot | ||||
Power | 110VAC 60Hz | ||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan fluor | 0.15 | 28mm | 1.5mm |
10X | plan fluor, phase-contrast | 0.30 | 3mm | 1.5mm |
20X | plan fluor, phase-contrast | 0.50 | 4.27mm | 1.5mm |
40X | plan fluor | 0.60 | 2.23mm | 1.5mm |
Camera Specifications | |
Sensor Type | CMOS (color) |
Sensor Optical Format | 1" |
Active Pixels | 9M (4096 x 2160) |
Pixel Size | 3.45µm x 3.45µm |
Active Sensor Area | 14.13mm x 7.45mm |
Shutter | global shutter |
Sensitivity | 1146mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 34fps @ 4096x2160 60fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|