AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination and 1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination and 2MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination and 3.1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination and 6.3MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination and 12MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-600X Magnification with Kohler Illumination and 20MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination and 1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination and 2MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination and 3.1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination and 6.3MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination and 12MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-900X Magnification with Kohler Illumination and 20MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination and 1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination and 2MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination and 3.1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination and 6.3MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination and 12MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1200X Magnification with Kohler Illumination and 20MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination and 1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination and 2MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination and 3.1MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination and 6.3MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination and 12MP Back-illuminated CMOS USB 3.0 Camera AmScope IN480 Series Inverted Infinity-Corrected Phase-Contrast Trinocular Compound Microscope 40X-1500X Magnification with Kohler Illumination and 20MP Back-illuminated CMOS USB 3.0 Camera
Key Features
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses provide magnifications ranging from 40X to 600X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- 40X to 600X magnification range using a quintuple lens turret for five unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X magnification range using a quintuple lens turret for five unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X magnification range using a quintuple lens turret for five unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X magnification range using a quintuple lens turret for five unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 600X magnification range using a quintuple lens turret for five unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 900X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- 40X to 900X expanded magnification range using a reversed quintuple lens turret and additional 15X eyepieces for nine unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 900X expanded magnification range using a reversed quintuple lens turret and additional 15X eyepieces for nine unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 900X expanded magnification range using a reversed quintuple lens turret and additional 15X eyepieces for nine unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 900X expanded magnification range using a reversed quintuple lens turret and additional 15X eyepieces for nine unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 900X expanded magnification range using a reversed quintuple lens turret and additional 15X eyepieces for nine unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide eight unique magnifications ranging from 40X to 1200X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- 40X to 1200X expanded magnification range using a reversed quintuple lens turret and additional 20X eyepieces for eight unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1200X expanded magnification range using a reversed quintuple lens turret and additional 20X eyepieces for eight unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 3.1MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1200X expanded magnification range using a reversed quintuple lens turret and additional 20X eyepieces for eight unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included highly-sensitive 6.3MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1200X expanded magnification range using a reversed quintuple lens turret and additional 20X eyepieces for eight unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included sensitive 12MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- 40X to 1200X expanded magnification range using a reversed quintuple lens turret and additional 20X eyepieces for eight unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included back-illuminated 20MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 1500X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- 40X to 1500X expanded magnification range using a reversed quintuple lens turret and additional 25X eyepieces for nine unique settings.
- A high performance inverted microscope with brightfield and phase-contrast for transmitted-light applications.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- The swing-out condenser holder can make room for larger specimen holders
- The infinity-corrected optical system ensures high-quality, high-resolution images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- The trinocular photo port provides a dedicated interface for mounting a camera.
- Monitor and capture photos and videos with the included ultra-sensitive 2MP USB 3.0 camera. Professional microscopy software for Windows, Mac, and Linux provide tools for image processing, measuring, and more.
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 1500X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- Includes a 3MP USB 3.0 camera with back-illuminated CMOS technology and specialized microscopy software for PC, Mac, and Linux
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 1500X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- Includes a 6.3MP USB 3.0 camera with back-illuminated CMOS technology and specialized microscopy software for PC, Mac, and Linux
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 1500X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- Includes a 12MP USB 3.0 camera with back-illuminated CMOS technology and specialized microscopy software for PC, Mac, and Linux
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 1500X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- Includes a 20MP USB 3.0 camera with back-illuminated CMOS technology and specialized microscopy software for PC, Mac, and Linux
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses provide a wide magnification range from 40X to 600X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 900X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 15X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
15X | 60X | 150X | 300X | 600X | 900X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1200X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 20X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
20X | 80X | 200X | 400X | 800X | 1200X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 25X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
25X | 100X | 250X | 500X | 1000X | 1500X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 25X eyepieces expand the maximum magnification to 1500X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 25X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 3MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The back-illuminated sensor is designed to maximize light-capture with minimal noise. This reduces exposure times and increases frame rates. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected |
Head | Trinocular, 45° incline |
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm |
Ocular Diameter | 30mm |
Eyepieces | 10X FN22mm plan wide-field 25X wide-field |
Photo-port | CX-type height-adjustable, 23mm tube |
Objective Turret | quintuple |
Focusing System | coaxial coarse and fine focus, adjustable tension |
Fine Focus Precision | 0.002mm |
Stage | fixed-height, mechanical X-Y translation |
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
Stage X-Y Travel Range | 120mm x 80mm |
Specimen Holders | Terasaki plate, Petri dish |
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
Condenser | NA 0.3, centerable |
Condenser Working Distance | 72mm maximum |
Phase Contrast Annuli | 4X/10X and 20X/40X |
Power | 90-240VAC 50/60Hz wide-band |
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Model | IMX123 (color) |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 6.3MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The back-illuminated sensor is designed to maximize light-capture with minimal noise. This reduces exposure times and increases frame rates. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected |
Head | Trinocular, 45° incline |
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm |
Ocular Diameter | 30mm |
Eyepieces | 10X FN22mm plan wide-field 25X wide-field |
Photo-port | CX-type height-adjustable, 23mm tube |
Objective Turret | quintuple |
Focusing System | coaxial coarse and fine focus, adjustable tension |
Fine Focus Precision | 0.002mm |
Stage | fixed-height, mechanical X-Y translation |
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
Stage X-Y Travel Range | 120mm x 80mm |
Specimen Holders | Terasaki plate, Petri dish |
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
Condenser | NA 0.3, centerable |
Condenser Working Distance | 72mm maximum |
Phase Contrast Annuli | 4X/10X and 20X/40X |
Power | 90-240VAC 50/60Hz wide-band |
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Model | IMX178 (color) |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 12MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The image sensor uses back-illuminated CMOS technology for improved light absorption and noise suppression. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 25X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
25X | 100X | 250X | 500X | 1000X | 1500X |
Camera Specifications
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 20MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The image sensor uses back-illuminated CMOS technology and a larger 1" optical format for improved light absorption and noise suppression. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 25X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
25X | 100X | 250X | 500X | 1000X | 1500X |
Camera Specifications
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Framerate | 15fps @ 5440x3648 50fps @ 2736x1824 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
camera pixel | N/A |
camera type | N/A |
compatibility | None |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-600X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Inverted |
product condition | NEW |
camera pixel | 2.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-600X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 3.1MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-600X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 6.3MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-600X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 12.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-600X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 20.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-600X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | N/A |
camera type | N/A |
compatibility | None |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-900X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
product condition | NEW |
camera pixel | 2.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-900X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 3.1MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-900X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 6.3MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-900X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 12.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-900X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 20.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-900X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | N/A |
camera type | N/A |
compatibility | None |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1200X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
product condition | NEW |
camera pixel | 2.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1200X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 3.1MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1200X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 6.3MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1200X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 12.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1200X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 20.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1200X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | N/A |
camera type | N/A |
compatibility | None |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1500X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
product condition | NEW |
camera pixel | 2.0MP |
camera type | USB 3.0 |
category | Microscope-Compound |
compatibility | PC & Mac |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1500X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
camera pixel | 3.1MP |
camera type | USB 3.0 |
compatibility | PC & Mac |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1500X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
camera pixel | 6.3MP |
camera type | USB 3.0 |
compatibility | PC & Mac |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1500X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
camera pixel | 12.0MP |
camera type | USB 3.0 |
compatibility | PC & Mac |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1500X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
camera pixel | 20.0MP |
camera type | USB 3.0 |
compatibility | PC & Mac |
condenser design | Kohler |
field view | Extreme Widefield |
illumination style | Transmitted (Bottom) |
light type | Halogen |
magnification power | 40X-1500X |
microscope optics | Achromatic , Plan , Infinity |
optics m | Achromatic , Plan , Infinity |
product condition | NEW |
specialty | Microscope-Phase Contrast , Microscope-Inverted |
Operating System | Software |
---|---|
Windows | v.10.11.2024 |
MAC | AmScopeAmLite_20240408.dmg |
SDK | TPG SDK (Optional) v.03.11.2024 |
Linux | AmScopeAmLite_x64_x84_20231115.tar |
AmScope products are warranted against manufacturer’s defects in material and workmanship from the original date of purchase, for the following years:
• Five Year Warranty for Microscopes: All our microscopes come with a five (5) year factory warranty against manufacturing defects, covering labor and parts.
• Ten Year Warranty for Euromex Microscopes: All our Euromex microscopes come with a ten (10) year factory warranty against manufacturing defects, covering labor and parts.
• One Year Warranty for Telescopes: All our telescopes come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Accessories: All our microscope accessories (USB cameras, illuminators, illumination, dust covers, and etc.) come with a one (1) year warranty, except when specified in the description.
• One Year Warranty for Items labeled as “Product Ships From Manufacturer”: All products that are shipped directly from the manufacturer come with a one (1) year warranty, except when specified in the description.
Warranty does not apply for consumable accessories and parts such as bulbs, batteries, fuses, cords, optical components or any add-on accessories such as mechanical specimen holders that are not built into the microscope stage as an integral part of the original manufacture, etc. Warranty does not cover microscopes, lenses cameras or other accessories that have become inoperable due to dirt or damage due to misuse or lack of maintenance.
Note: Buyers are responsible for return shipping and handling cost for warranty services. Our warranty covers parts and labor only.
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses provide a wide magnification range from 40X to 600X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 900X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 15X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
15X | 60X | 150X | 300X | 600X | 900X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 15X eyepieces expand the maximum magnification to 900X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 15X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1200X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 20X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
20X | 80X | 200X | 400X | 800X | 1200X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 3.1MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3.1M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 6.3MP USB3.0 camera. The highly-sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.5X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048, 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 12MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. A 0.75X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000, 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 20X eyepieces expand the maximum magnification to 1200X with 8 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included high-resolution 20MP USB3.0 camera. The sensitive back-illuminated sensor is designed for improved low-light imaging, making it suitable for fluorescence and darkfield microscopy. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 20X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 15fps @ 5440x3648, 50fps @ 2736x1824, 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 1X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 25X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
25X | 100X | 250X | 500X | 1000X | 1500X |
Contents
The IN480T provides high-resolution optics and a versatile inverted Koehler illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens in brightfield and phase-contrast. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images. The advanced Koehler illumination system provides centering and aperture controls, as well as a swing-out condenser-holder to fully optimize the lighting for any scenario.
The Viewing Head
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. Super-widefield optics provide a larger field-of-view so you can see more specimen at any magnification. For users with astigmatism or asymmetrical vision, the left ocular can be adjusted to fine-tune focus. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos. A sliding shutter isolates the light path when using a camera, avoiding stray light from the oculars during fluorescence imaging. The 23mm photo port is height-adjustable to match focus with the eyepieces, and can be replaced with an optional CX series C-mount port which have built-in reduction, and can directly interface with C-mount cameras.
Optics
The infinity-corrected optical system eliminates optical errors and ensures highly precise images. The quintuple objective turret provides instant access to 5 magnification levels. This allows you to efficiently move through magnifications from 40X to 600X. Additional 25X eyepieces expand the maximum magnification to 1500X with 9 unique levels. These high-quality lenses are achromatically corrected to improve resolution and color accuracy, with planatic flat-field correction to provide edge-to-edge sharpness.
The Stage
The large stage can accommodate slides, multi-well plates, dishes, and short flasks thanks to a number of included stage templates. Two plates are supplied for the stage’s aperture, including glass and key-holed metal for varying light control. A large mechanical caliper can hold and position any of the sample templates for precision placement. An extension is provided for an additional 70mm width when needed.
Koehler Transmitted Illumination
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
Digital Imaging
Monitor and capture photos and videos with the included 2MP USB3.0 camera. With extraordinary sensitivity and a maximum framerate of 125fps, the MU203-BI provides high-definition imaging for low-light applications, including fluorescence and darkfield. Using a cutting-edge 2MP back-illuminated CMOS sensor with an incredible 2350mV sensitivity (1/30s), high gain-levels can be used for highly-responsive realtime video. A 0.37X reduction lens is included to capture more of the microscope's field-of-view. Our professional software for Windows provides a wide assortment of capture and photo-editing functions including color correction, time-lapse capture, image stitching, and a full complement of measuring tools. A lite version of our software is available for Mac and Linux with essential functionality for capturing photos and videos.
Specifications
Technical drawings with measurements (in mm)
Optical System | Infinity-corrected | ||||||||
Reference Focal Length | 220mm | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Ocular Diopters | left ocular | ||||||||
Eyepieces | 10X, 25X | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Lenses | Infinity-corrected | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 2M (1920 x 1080) |
Pixel Size | 2.9µm x 2.9µm |
Active Sensor Area | 5.57mm x 3.13mm |
Shutter | electronic rolling shutter |
Sensitivity | 1300mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 125fps @ 1920x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Packing List:
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 3MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The back-illuminated sensor is designed to maximize light-capture with minimal noise. This reduces exposure times and increases frame rates. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected |
Head | Trinocular, 45° incline |
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm |
Ocular Diameter | 30mm |
Eyepieces | 10X FN22mm plan wide-field 25X wide-field |
Photo-port | CX-type height-adjustable, 23mm tube |
Objective Turret | quintuple |
Focusing System | coaxial coarse and fine focus, adjustable tension |
Fine Focus Precision | 0.002mm |
Stage | fixed-height, mechanical X-Y translation |
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
Stage X-Y Travel Range | 120mm x 80mm |
Specimen Holders | Terasaki plate, Petri dish |
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
Condenser | NA 0.3, centerable |
Condenser Working Distance | 72mm maximum |
Phase Contrast Annuli | 4X/10X and 20X/40X |
Power | 90-240VAC 50/60Hz wide-band |
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Model | IMX123 (color) |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/2.8" |
Active Pixels | 3M (2048 x 1536) |
Pixel Size | 2.5µm x 2.5µm |
Active Sensor Area | 5.12mm x 3.84mm |
Shutter | electronic rolling shutter |
Sensitivity | 600mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 50fps @ 2048x1536 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 6.3MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The back-illuminated sensor is designed to maximize light-capture with minimal noise. This reduces exposure times and increases frame rates. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected |
Head | Trinocular, 45° incline |
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm |
Ocular Diameter | 30mm |
Eyepieces | 10X FN22mm plan wide-field 25X wide-field |
Photo-port | CX-type height-adjustable, 23mm tube |
Objective Turret | quintuple |
Focusing System | coaxial coarse and fine focus, adjustable tension |
Fine Focus Precision | 0.002mm |
Stage | fixed-height, mechanical X-Y translation |
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
Stage X-Y Travel Range | 120mm x 80mm |
Specimen Holders | Terasaki plate, Petri dish |
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
Condenser | NA 0.3, centerable |
Condenser Working Distance | 72mm maximum |
Phase Contrast Annuli | 4X/10X and 20X/40X |
Power | 90-240VAC 50/60Hz wide-band |
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Camera Specifications | |
Model | IMX178 (color) |
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.8" |
Active Pixels | 6.3M (3072 x 2048) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 7.37mm x 4.92mm |
Shutter | electronic rolling shutter |
Sensitivity | 425mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 30 fps @ 3072x2048 38fps @ 1536x1024 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.5X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 12MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The image sensor uses back-illuminated CMOS technology for improved light absorption and noise suppression. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 25X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
25X | 100X | 250X | 500X | 1000X | 1500X |
Camera Specifications
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1/1.7" |
Active Pixels | 12M (4000 x 3000) |
Pixel Size | 1.85µm x 1.85µm |
Active Sensor Area | 7.4mm x 5.55mm |
Shutter | electronic rolling shutter |
Sensitivity | 280mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Maximum Framerate | 25fps @ 4000x3000 50fps @ 2048x1080 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Compensating Lens | 0.75X |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 20MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. The image sensor uses back-illuminated CMOS technology and a larger 1" optical format for improved light absorption and noise suppression. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System | Infinity-corrected | ||||||||
Head | Trinocular, 45° incline | ||||||||
Interpupillary Adjustment | Siedentopf compensation-free gemel, 50mm-76mm | ||||||||
Ocular Diameter | 30mm | ||||||||
Eyepieces | 10X FN22mm plan wide-field, 25X wide-field | ||||||||
Photo-port | CX-type height-adjustable, 23mm tube | ||||||||
Objective Turret | quintuple | ||||||||
Focusing System |
|
||||||||
Stage | fixed-height, mechanical X-Y translation | ||||||||
Stage Dimensions | 160mm x 250mm stage extension: 70mm x 180mm |
||||||||
Stage X-Y Travel Range | 120mm x 80mm | ||||||||
Specimen Holders | Terasaki plate, Petri dish | ||||||||
Transmitted Illumination | 6V 30W halogen variable intensity centerable lamp |
||||||||
Condenser | NA 0.3, centerable | ||||||||
Condenser Working Distance | 72mm maximum | ||||||||
Phase Contrast Annuli | 4X/10X and 20X/40X | ||||||||
Power | 90-240VAC 50/60Hz wide-band | ||||||||
Objective Lenses
Magnification | Corrections | NA | Working Distance | Cover-glass Thickness |
---|---|---|---|---|
4X | plan achromatic | 0.13 | 10.4mm | 1.5mm |
10X | plan achromatic | 0.25 | 7.30mm | 1.5mm |
20X | plan achromatic | 0.40 | 6.79mm | 1.5mm |
40X | plan achromatic | 0.60 | 3.08mm | 1.5mm |
60X | plan achromatic | 0.70 | 1.71mm | 1.5mm |
10X | phase-ring | 0.25 | 7.30mm | 1.5mm |
20X | phase-ring | 0.40 | 6.80mm | 1.5mm |
40X | phase-ring | 0.60 | 3.08mm | 1.5mm |
Magnification Chart
Eyepiece | Objective | ||||
4X | 10X | 20X | 40X | 60X | |
10X | 40X | 100X | 200X | 400X | 600X |
25X | 100X | 250X | 500X | 1000X | 1500X |
Camera Specifications
Sensor Type | Back-illuminated CMOS |
Sensor Optical Format | 1" |
Active Pixels | 20M (5440 x 3648) |
Pixel Size | 2.4µm x 2.4µm |
Active Sensor Area | 13.06mm x 8.76mm |
Shutter | electronic rolling shutter |
Sensitivity | 462mV @ 1/30s |
Spectral Response | 380-650nm with IR-cut filter |
Capture Resolution and Framerate | 15fps @ 5440x3648 50fps @ 2736x1824 60fps @ 1824x1216 |
Connectivity | USB 3.0 |
Lens-mount | C-mount |
Power | 5VDC over USB |
Software
OS Requirements | Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hardware Requirements | Intel Core2 2.8GHz or comparable processor, 4GB RAM | ||||||||||||||||||
Features |
|
Contents